Control Console. DICC-XX, OCCC-XX, OICC-XX Devices

Purpose The Double-Dipslayed Integrated Control Consoles (DICC) are multi-function ones and designed to create workstations (WS) of operator's and to use them within computer-aided packages of fixed and mobile, C2 centers and operations posts.


The integrated control consoles are represented by the following product line: DICC-1, DICC-2, DICC-3, DICC-4, DICC-5, OICC, and OCCC.
Basic functions and technical characteristics
  • - Display of all types of data entered by operator and received from sources.
  • - Control of form and modes of data display.
  • - Entry of textual and symbolic information.
  • - Entry of graphic data.
  • - Display of e-chart..
  • - Information support of operator's work when solving application and calculation tasks.
  • - Adaptation to a particular list of application tasks using set of program-adjustable dialog facilities.
  • - Identification of operators in subsystem of control of access to data by means of software and hardware.
  • - Monitoring of unauthorized access.
  • - Off-line and remote power up / down.
  • - Monitoring of operability and fault diagnostics.
  • - Connection to LAN of data exchange. The network type is Ethernet.
DESIGN FEATURES

The DICC-1 can be made with a touch panel and without it. The components of the DICC are installed on the table (which is not a part of the control console).

The DICC-2 has a range of versions which differ in availability of touch panel, control and diagnostics facilities, and remote power up/down facilities.

The components of the DICC, except for system unit, are located in a table-mounted support. The table is not a part of the control console. The monitoring and control panel P.KU.01, designed to ensure the System power up/down with the help of corresponding controls, and System status indication «NETWORK» and «ON«, is installed in the right part of the support.

The distribution and switching panel designed for distribution of power supply between components (channels) of the System is located in the central support part, as well as for power supply control of the DICC components in local and remote modes with protection against overload and short circuits, and indication of availability of power supply by each channel. The feed panel, module for access to resources, diagnostics and monitorring (M–2I.KHK.101) are placed in the left part of the support.

The video monitors are installed on a bracket (on a support) and fixed.

The column speakers are placed on the table.

In the DICC-3 and DICC-4 versions, the table bears on four high-adjusting supports to provide the steady state position. To provide shock protection, the table bears on four shock mounts.

To provide the DICC-3 steady position, two shock mounts are provided. They are placed on the rear wall of the table. The DICC-3, designed for operation under external factors environment, is jointly used with a seismic-shock protection kit.

The Technical Characteristics of the DICC-1, DICC-2, DICC-3, and the DICC-4 are given in the table below.

DICC-1 Designed to equip computer-aided packages of day-to-day control posts (CP).



DICC-2 Designed to equip computer-aided packages of day-to-day CPs.



DICC-3 Designed to equip computer-aided packages of day-to-day and main secure CPs.



DICC-4 Designed to equip computer-aided packages of day-to-day CPs.



OICC Used as part of computer-aided packages at fixed CPs.



DICC-5 The equipment (video monitors) is mounted in floor-installed vertical metal cabinet. Designed to equip computer-aided packages for fixed and mobile CPs.



OCCC The OCCC is designed to equip computer-aided packages of fixed and mobile C2 centers and operations posts.

It has been developed on basis of a potable computer.
КThe OCCC design is made on basis of a special support designed for placement and fastening of access control unit, power supply unit of portable computer, input supply cable and connecting bundles.
The support design allows to avoid access to HDD and connectors on the rear panel of the portable computer. The access to DWD-ROM, USB-ports on side panels of portable computer is blocked by means of a special hinged cover. The covers are fixed by screw-down screws and sealed, and are protected by sensors of unauthorized access.

Devices allow their use in various climatic conditions

Parameter Value
DICC-1 DICC-2 DICC-3 DICC-4
Computing unit:
- type and architecture of processor Intel х86 Intel х86 Intel х86 Intel х86 Intel х86
- clock rate of processor, GHz, not less than 2,3 2,8 2,8 2,8 2,8
- RAM capacity, Mbyte, no less than 1024 1024 1024 1024 1024
- HDD capacity, Gb, no less than 80 80 80 120 80
- number of interface channels Fast Ethernet, pcs. 2 2 2 2 2
- number of interface channels RS-232, pcs. 4 4 4 4 4
LCD video monitor
- size, inch, not less than 19 24 19 24 19 21 19 21 23 24
- resolution, dot, no less than 1280 х 1024 1280 х 1024 1280 х 1024 1280 х 1024 1280 х 1024
- viewing angle, deg, no less than ±70 ±70 ±70 ±70 ±70
- brightness, cd/m2, no less than2 300 300 300 300 300
- contrast, no less than 700/1 700/1 700/1 700/1 700/1
LCD touch video monitor
- number, pcs. 0 1 0 1 0 1 0 1 1
- size, inch 10,4 12 – 15 12 12 17
- resolution, dot, no less than 640 х 480 800 х 600,
1024 х 768
800 х 600 800 х 600 1024 х 768
- viewing angle, deg, no less than ±55 ±55 ±55 ±55 ±55
- brightness, cd/m2, no less than 250 250 250 250 250
- contrast, no less than 500/1 500/1 500/1 500/1 500/1
Alphanumeric keyboard
- attached unit interface PS/2 PS/2 PS/2 PS/2 PS/2
Manipulator of graphic information:
- attached unitinterface PS/2 PS/2 PS/2 PS/2 PS/2
Monitoring and control facilities: module for access to resources, monitoring and diagnostics M-2I.KHK.101
- functions: monitoring of technical state;
monitoring of temperature mode;
monitoring of unauthorized access;
control of power up/down;
diagnostics of product
- interface of diagnostic network, pcs. RS-485, 1 pc.
Operating system Linux, МСВС
Power supply parameters:
- voltage, V
- frequency, Hz
- power consumption, W, no more than

198 242
49 ‒ 51
400

198 242
49 ‒ 51
400

198 242
49 ‒ 51
400

198 242
49 ‒ 51
400

192 242
49 ‒ 51
400
24-hour operation at ambient temperature:
- minimum,°С
- maximum, °С

+10
+25

+10
+25

+10
+25

+5
+40

+10
+25
MTBF, h, no less than 10 000 10 000 10 000 10 000 10 000
Recovery time, min, no more than,
min, no more than
30 30 30 30 30
Dimensions:
- width, mm
- depth, mm
- height, mm
1200
700
1216
1200
700
1216
1350
810
1216
1416
886 (973*)
1311 (1405*)
1350
810
1216
Weight, kg, no more than 50 50 130 150 (170*) 130

Parameter Value
DICC-5 OCCC OICC
Computing unit:
- clock frequency of processor, GHz, no less than 1,4 2,8 2,6
- RAM capacity, Mbyte, no less than 2048 2048 8192
- HDD (SSD) capacity, Gb, no less than 160 120 1000
- number of interface channels Fast Ethernet, pcs. 2 2 1
- number of interface channels RS-232, pcs. 4 2
- number of interface channels VGA, pcs, no less than 1 1
LCD touch video monitor:
- number, pcs. 2 1 1
- size, inch 21 15 – 17 23 – 24
- resolution, dot, no less than 1600 х 1024 1024 х 768 1920 х 1080
- viewing angle, deg., no less than ±85 ±70 ±70
- brightness, cd/m2, no less than 300 300 300
- contrast, no less than 700/1 700/1 700/1
LCD touch video monitor
- number, pcs. 1
- size, inch 12
- resolution, dot, no less than 800 х 600
- viewing angle, deg., no less than ±80
- brightness, cd/m2, no less than 450
- contrast, no less than 700/1
Alphanumeric keyboard:
- attached unit interface PS/2 USB
Manipulator of graphic information:
- attached unit interface PS/2 PS/2 PS/2
Monitoring and control facilities: module for access to resources, monitoring and diagnostics M-2I.KHK.101
- monitoring and control functions: monitoring of technical state;
monitoring of temperature mode;
monitoring of unauthorized access;
control of power up/down;
diagnostics of product
- interface of diagnostic network, pcs. RS-485, 1 pc.